GovWin Capture Management Integration Connection Settings

After applying the hotfixes and files for integration, new and existing users must enter the proper connection settings in the Costpoint 7.1.1 Configuration Utility to enable integration using Capture Management web services.

Attention: For more details on the required hotfixes and files, please refer to the Minimum System Requirements section of the Deltek Costpoint 7.1.1 to GovWin Capture Management (Web Service) Integration Technical Guide.

To configure the Costpoint to GovWin Capture Management Integration connection settings:

  1. On your Costpoint application server, click Start > All Programs > Costpoint 7.1.1 > Start Costpoint 7.1.1 Config Utility.
    Due to enhanced security in Windows Server 2008, Deltek recommends that you use the Run as Administrator option when launching this command even when the logged in user has local administrative rights.
  2. On the Select Your Configuration Options screen, make sure the Costpoint Application Configuration check box is selected and click Next.
    The check box is selected by default.
  3. Click Costpoint tab > GovWin CM tab, and then enter the connection settings for the Costpoint to GovWin Capture Management Integration:
    OptionDescription
    Use GovWin CM Integration Select this check box to enable integration with GovWin Capture Management.
    GovWin CM Web Service URL Enter the URL for the GovWin Capture Management Web Service. For example, enter http://SERVERNAME/vision/visionws.asmx, where SERVERNAME is the name of your GovWin Capture Management application server.
    User Enter DELTEKCPINTEGRATION.
    Warning: You must enter the DELTEKCPINTEGRATION user ID in the User field in order for the connection and integration to work properly. For the purposes of this integration, you must create a DELTEKCPINTEGRATION user account with FULL rights in GovWin Capture Management .
    Password and Confirm Password Enter and confirm the password of the DELTEKCPINTEGRATION user account.
    Database Name Enter the GovWin Capture Management database name.
    Number of Rows Per Call The default value is 100. This indicates how many records are transformed before Costpoint sends them to GovWin Capture Management.
    Connection Timeout The default value is 10 seconds. This indicates the amount of time Costpoint will wait for GovWin Capture Management to respond during a connection.
    Request Timeout The default value is 10 seconds. This indicates the amount of time Costpoint will wait for GovWin Capture Management to respond when transferring data.
  4. Click Test to check if the settings are correct.
  5. When the Connected message displays, click OK.
  6. Click Save, and then click OK on the screen to confirm that all changes were saved.
  7. Click Close.
  8. Restart all WebLogic servers or run the Rebuild Global Settings screen in Costpoint Administration to allow the changes to take effect.
Attention: For more information on using the Costpoint Configuration Utility application, please refer to the Deltek Costpoint 7.1.1 Configuration Utility guide.