Use this subtask to view the Engineering Bills of Material (EBOM) components of the selected part to be changed by the ECN. If no components exist for the assembly part, you can copy components from an existing MBOM or EBOM assembly, or add new component lines manually.
This field displays the ECN ID from the main screen. The unlabeled field to the right displays the ECN description from the main screen.
This field displays the part ID from the main screen. If the Action Code is "O - Obsolete" or "C - Change" in the main screen, this field displays the original part ID. If the Action Code is "A - Add," "R - Replace," or "V - New Rev" in the main screen, this field displays the change-to part ID.
The part description displays in the unlabeled field beneath this field.
This field displays the part revision from the main screen.
Select the EBOM status (i.e., "Released" or "Unreleased") of the selected assembly part from the drop-down box. This field is required, but can be changed. The default is the value of part's assembly release flag. If the Action Code is "A - Add," "R - Replace," or "V - New Rev" in the main screen, this field defaults with the value from the Change-To EBOM Status field in the main screen. If the Action Code is "C - Change" or "O - Obsolete" in the main screen and the Original Part is an EBOM assembly, this field defaults with the original part's BOM Status from the Maintain EBOM screen. All component parts must be released (i.e., the Component Released field must be "Y" for all lines) in order for the EBOM Status to be "Released."
If the Action Code is "A - Add," "R - Replace," or "V - New Rev" for the selected line in the main screen, this field will default with the value from the Change-To Status field. If the Action Code is "C - Change" or "O - Obsolete" for the selected line in the main screen, this field will default with the value from the Original Part Status field.
If the Action Code in the main screen is "O - Obsolete" or "C - Change," the original part's EBOM components will default into this table window if the Original Part is an EBOM assembly. If the Action Code in the main screen is "A - Add," "R - Replace," or "V - New Rev," the change-to part's EBOM components will default into this table window if the Change-to Part is an EBOM assembly. If no components exist for the Assembly Part, you can copy components from an existing MBOM or EBOM assembly, or add new component lines manually.
Select from the drop-down box the action this ECN will perform, either "A - Add," "C - Change," "D - Delete," or "O - Obsolete." When you add a new line, the default is "A - Add." If the table window defaults with the EBOM components for the original part or change-to part, this field will be blank depending on the Action Code in the main screen.
Enter up to four digits of the line number to identify the specific EBOM component line. This field is required. If the part in header has EBOM components, this field takes the value from BOM structure.
Enter up to four alphanumeric characters of the drawing find number used for this EBOM component line. Upon populating the Line field for a new line, this field will default with zeroes, but can be changed. For example, if you enter "3" in the Line field, the Find field will default to "0003." This field is optional.
You can enter both standard and provisional parts in this field. Enter, use Lookup, or use the Lookup Prov Part pushbutton to select, the component part ID used on this EBOM line. This optional field of up to 30 alphanumeric characters must be a valid part ID from the Basic Part Data screen (for standard parts) or the Maintain Provisional Parts screen (for provisional parts) in Costpoint Product Definition. If the part in the header already has EBOM components, this field populates from the BOM structure. You can add new components.
Enter, use Lookup, or use the Lookup Prov Part pushbutton to select, the component part revision used on this EBOM line. This optional field of up to three alphanumeric characters must be part of a valid part/revision combination from the Basic Part Data screen (for standard parts) or the Maintain Provisional Parts screen (for provisional parts) in Costpoint Product Definition.
Enter the component type code: "B" (Buy With Component), "S" (Standard), "P" (Phantom), "R" (Reference), "T" (Tool), or "D" (Deleted). This field is required. The default takes the code associated with the component part from the Basic Part Data screen in Costpoint Product Definition (for standard parts), or the Maintain Provisional Parts screen (for provisional parts).
Enter the quantity type code: "A" (Per Assembly), "R" (As Required), or "O" (Per Order). This field is required. If you have selected the As Required checkbox in the Basic Part Data screen in Costpoint Product Definition for the component part, or the Comp Type is "R" (Reference), the default for this field is "R." If the Comp Type is "T" (Tool), the default for this field is "O." Otherwise, the default is "A."
Enter up to 14 digits, including two digits after the decimal point, for the component part quantity required in the EBOM. This field is required. The default is "1." If the Qty Type is "R," the default is zero.
This field displays the inventory unit of measure for the component from the Basic Part Data screen in Costpoint Product Definition.
Enter "M" (Make) if the component is to be manufactured or "B" (Buy) if it is to be purchased. This field is required. The default takes its value from the component part.
Enter, or use Lookup to select, the ID of the configuration in which this component will be used when planning this EBOM. This optional field of up to 10 alphanumeric characters must be a valid ID from the Configuration Identifiers screen in Costpoint Bills of Material. If you did not select the Use Configuration IDs checkbox in the BOM Corporate Settings subtask of the BOM Settings screen in Costpoint Bills of Material, this field is hidden.
This field displays the configuration description. If you did not select the Use Configuration IDs checkbox in the BOM Corporate Settings subtask of the BOM Settings screen in Costpoint Bills of Material, this field is hidden.
Enter the effective date for this component in the EBOM. This field is required. For new rows whose Action Code is "A - Add," the default will be the Effective Date from the main screen. If the Effective Date is null, the Suggested Effective Date in the ECN Detail subtask will display. If the Action Code is blank and a component part exists, the EBOM component's Effective Starting Date will display.
Enter the date on which this component will cease being effective in this EBOM. This is an optional field that defaults with the EBOM component's Effective Ending Date (if the date exists). If the Action Code is "O - Obsolete," this field defaults with the Suggested Effective Date from the ECN Detail subtask (if populated).
Enter "Y" (Yes) to release this component in this EBOM, or "N" (No) to keep it unreleased. This is a required field. The default value is determined by the radio button selected in the EBOM Release Control - Default Component Release Status in Bill group box in the BOM Settings screen of Costpoint Bills of Material.
If you did not select the Use Extended Length Reference Designators checkbox in the BOM Corporate Settings subtask of the BOM Settings screen, enter up to 254 alphanumeric characters of reference designator text for this component on this assembly. This field is optional. However, if you selected the Use Extended Length Reference Designators checkbox, you can enter up to 32,000 alphanumeric characters in this field. This field displays any reference designator text that was assigned for the component part line in the Component Reference Designators subtask of the Maintain EBOM and/or Release EBOM screen.
Enter up to 254 alphanumeric characters for any comments that apply to this EBOM component. This field is optional. This field will display any comments already entered for the EBOM component.
Enter "Y" (Yes) in this required field to prevent material planning processes from planning this component. If the component is a buy part, and the Comp Type is not "B" (Buy With Component), the default is "Y" (Yes). If the Comp Type is "R" (Reference) or "T" (Tool), the default is also "Y" (Yes). Otherwise, the default is "N" (No).
Enter "Y" (Yes) in this required field to prevent material planning processes from planning any components of this subassembly part. If the Comp Type is "R" (Reference) or "T" (Tool), the default is "Y" (Yes). Otherwise, the default is "N" (No).
Enter the anticipated scrap percentage used when planning material requirements. This field is required. The default takes value from the Planning Part Data screen in Costpoint Product Definition.
Enter "Y" (Yes) in this required field to copy all other original EBOM data to a new line. The default is "N" (No) unless the component was copied from another EBOM.
This field displays a description of the component part.
If the component part is a provisional part, this field displays the provisional part type that is assigned to the provisional part ID. You can change this field only in the Maintain Provisional Parts screen. Otherwise, this field is blank.
Select this pushbutton to lookup a provisional part ID or revision when the cursor is in the Component Part or Comp Rev fields.
Select this pushbutton to open a subtask where you can copy a MBOM from another part/revision. This pushbutton is disabled if component lines already exist for the assembly part.
Select this pushbutton to open a subtask where you can copy an EBOM from another part/revision. This pushbutton is disabled if component lines already exist for the assembly part.